|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
R/SEC/R011.S06/A/4/10/2000 RELAIS REED A CONTACT SEC REED RELAY / DRY CONTACT Pour circuit imprime/ page 1 / 2 F/GB For printed circuit board Un contact normalement ouvert/ R011 . S06 One normally open contact sous capot metal/ In metal cover caracteristisques principales/ main characteristics tension maximale de commutation/ maximum switching voltage courant maximal de commutation / maximum switching current puissance maximale/ contact rating 250 VAC ou crete (or peak) 3A REF. Marquage/Marking R0115S06 150 R06 115A R0116S06 150 R12 116A R0117S06 150 R12 117A courant traversant/ nominal current 5A 100 W materiau de contact/ contact material Rhodium 65 15,5 50,8 O1 5,08 6 16 dimensions en mm / dimensions in mm bornage : vue de dessus pas de 5,08 mm wiring : top view step 5,08 mm caracteristiques de controle/control data REF. tension max/ maximum voltage (V) tension nominale/ nominal voltage (V) tension d'action/ operate voltage to secure the function from -40 to + 85 C (V) tension de relachement/ release voltage (V) consommation nominale a 20 C/power dissipated on the coil at 20 C (mW) R0115 9 6 4,4 1,2 150 R0116 18 12 8,8 2,4 150 R0117 36 24 17,6 4,8 150 Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. r celduc e l a i s R/SEC/R011.S06/A/4/10/2000 page 2 / 2 F/GB caracteristiques electriques/electrical data resistance initiale de contact/ Initial contact resistance ( 100 mA/ 12 VAC) 50 m resistance de bobine/coil resistance at 20 C REF. R0115 R0116 R0117 -variation 10 % each 25 C 250 1000 4000 tension de tenue/ hold-on voltage - entre lames/ accross contacts - entre bobine et contact/ between coil and contacts - entre boitier et contact /between case and contacts - entre boitier et bobine/ between case and coil resistance d'isolement/ insulation resistance - entre lames/ accross contacts - entre bobine et contact/ between coil and contacts - entre boitier et contact /between case and contacts - entre boitier et bobine/ between case and coil frequence de resonnance de l'interrupteur/ resonnance frequency of the switch temps de fermeture, rebonds inclus/ operate time, bounces included temps d'ouverture/ release time Duree de vie electrique/ Electrical life time Duree de vie mecanique/ mecanical life expectancy voltage 5V 500 Vac 500 Vac 500 Vac 500 Vac 1010 1010 1010 109 800 Hz 2,5 ms 0,1 ms 250V 140mA > 45.106 op 110V = 460mA > 3,3 106 >1. 109 op 30 V 200 100 VAC 60 caracteristiques physiques/ physical data current ( mA ) 10 life expectancy ( - x 106 op. ) 200 temperature de fontionnement/-9 operating temperature rate of failure ( - x 10 defaut / op.) 5 temperature de stockage/ storage temperature poids/ weight chocs/shocks (11ms) vibrations ( 10 to 500 Hz ) 180 830 - 40 a + 85 C 5,6 1,2 - 40 a + 100 C 30 gr. max. 100 g 20 g celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of R0116S06 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |